Since this is a 40’ container and sitting across both 9 and 11 bays, this bay is given the number 10. The container is shown as sitting on 9 but the corresponding slot on 11 is marked with an X which means that this slot is NOT available for placing another container because there is a 40’ container already there. Definition of SLOT in the Definitions.net dictionary. Meaning of SLOT. What does SLOT mean? Information and translations of SLOT in the most comprehensive dictionary definitions resource on the web.
Holes or slots in the arrow side member of a joint for plug or slot welding must be indicated by placing the weld symbol on the side of the reference line toward the reader (A, fig. 3-11).
Holes or slots in the other side member of a joint shall be indicated by placing the weld symbol on the side of the reference line away from the reader (B, fig. 3-11).
Neither the plug weld symbol nor the slot weld symbol may be used to designate fillet welds in holes.
Dimensions of plug welds must be shown on the same side of the reference line as the weld symbol. The size of a weld must be shown to the left of the weld symbol.
The included angle of countersink of plug welds must be the user’s standard unless otherwise indicated.
The included angle of countersink, when not the user’s standard, must be shown either above or below the weld symbol (A and C, fig. 3-34).
The pitch (center-to-center spacing) of plug welds shall be shown to the right of the weld symbol.
Depth of filling of plug and slot welds shall be completed unless otherwise indicated. When the depth of filling is less than complete, the depth of filling shall be shown in inches inside the weld symbol (B, fig. 3-34).
Plug welds that are to be welded approximately flush without recourse to any method of finishing must be shown by adding the finish contour symbol to the weld symbol (fig. 3-35).
Plug welds that are to be welded flush by mechanical means must be shown by adding both the flush contour symbol and the user’s standard finish symbol to the weld symbol (fig. 3-36).
Dimensions of slot welds must be shown on the same side of the reference line as the weld symbol (fig. 3-37).
Length, width, spacing, included angle of countersink, orientation, and location of slot welds cannot be shown on the welding symbols.
This data must be shown on the drawing or by a detail with a reference to it on the welding symbol, in accordance with location specifications given in paragraph 3-7 (D, fig. 3-33).